KB96: Coil-equipped dies

Category: Miscellaneous Tips | Updated: 6/12/2007 8:27:38 AM | Owner: The Professor | Read: 2864 (Last: 10/30/2014 2:40:57 PM)

Resolution

In shifting from hand fed operations to coil fed, there is more than the change of thinking involved that many of our previous tips have hinted at. The chances of using previous dies without significant modification are remote. Guides and strippers must accept the automatic positioning. Pilots should be used to eliminate potential progressive error where appropriate.